Direkt zum Inhalt

VDI 2463 Blatt 7 Particulate matter measurement - Determination of suspended particulate matter and gaseous chemical compounds in ambient air and indoor air - Active sampling via low-volume sampler (LVS)

At a glance

German title
Messen von Partikeln - Erfassung von Schwebstaub und gasförmigen chemischen Verbindungen in Außenluft und Innenraumluft - Aktive Probenahme mittels Low-Volume-Sampler (LVS)
Publication date
2014-05
Publisher
Engl. VDI/DIN-Kommission Reinhaltung der Luft (KRdL) - Normenausschuss
Author
Technical Division Environmental Measurement Technologies
Related manuals
Number of pages
10
Available in
German, English
Abstract

Owing to legal requirements such as the Federal Immission Control Act (BImSchG), the monitoring of suspended particulate matter with aerodynamic particle diameters < 10 µm and < 2,5 µm microns is of the utmost importance. The standard specifies requirements for a sampling device for active sampling of suspended particulate matter, dust components and selected gaseous compounds (e.g. polychlorinated dioxins) in ambient air and indoor air. It gives technical specifications, requirements for components and tolerances concerning volume flow (2,3 m<(hoch)3>/h to 3,0<(hoch)3>/h) of the sampling device low-volume sampler (LVS).

View Table of Contents (PDF file)

Purchase VDI Standard

Price
59,10 EUR VAT included
Purchase now

FAQ